Advantages

Coriolis flowmeters have the following advantages:

1. They are capable of measuring a range of fluids that are often incompatible with other flow measurement devices. The operation of the flowmeter is independent of the Reynolds number; therefore, extremely viscous fluids can also be measured. A Coriolis flowmeter can measure the flow rate of Newtonian fluids, all types of nonNewtonian fluids, and slurries. Compressed gases and cryogenic liquids can also be measured by some designs.

2. Coriolis flowmeters provide a direct mass-flow measurement without the addition of external measurement instruments. While the volumetric flow rate of the fluid varies with changes in density, the mass-flow rate of the fluid is independent of density changes.

3. Coriolis flowmeters have outstanding accuracy. The base inaccuracy is commonly 0.2%. In addition, the flowmeters are extremely linear over their entire flow range.

4. The rangeability of the flowmeters is usually 20:1 or greater. Coriolis flowmeters have been successfully applied at flow rates 100 times lower than their rated full-scale flow rate.

5. A Coriolis flowmeter is capable of measuring mass-flow rate, volumetric flow rate, fluid density, and temperature—all from one instrument.

6. The operation of the flowmeter is independent of flow characteristics such as turbulence and flow profile. Therefore, upstream and downstream straight run requirements and flow conditioning are not necessary. They can also be used in installations that have pulsating flow.

7. Coriolis flowmeters do not have internal obstructions that can be damaged or plugged by slurries or other types of particulate matter in the flow stream. Entrained gas or slugs of gas in the liquid do not damage the flowmeter. The flowmeter has no moving parts that wear out and require replacement. These design features reduce the need for routine maintenance.

8. The flowmeter can be configured to measure flow in either the forward or reverse direction. In reverse flow, a time or phase difference occurs between the flow detector signals, but the relative difference between the two detector signals is reversed.

9. Coriolis flowmeter designs are available for use in sanitary applications and for the measurement of shear sensitive fluids. Materials are available that permit the measurement of corrosive fluids.